About Us | News | Download | Contact Us
Availability: | |
---|---|
Quantity: | |
Flanged Magnetic Flow Meter provide highly accurate flow measurement for a wide variety of conductive fluid applications. Magnetic Water Flow Meter is a volumetric flow meter that measures liquids or liquid slurries that have a minimum conductivity of 5 µS/cm. Based on Faraday’s law of electromagnetic induction. Magnetic Water Flow Meter is ideal for wastewater applications or any dirty liquid which is conductive or water based. It is widely used in water treatment, environmental protection sewage measurement and control, papermaking and other industrial and agricultural production processes for flow measurement and control.
Not affected by changes in fluid density, viscosity, temperature, pressure and conductivity. The linear measurement principle can achieve high-precision measurement;
There are no flow blocking parts in the measuring pipe. The pressure loss is small, and the requirements for straight pipe sections are low;
Nominal diameter DN6-DN3000 covers a wide range. There are many choices of lining and electrodes. It can meet the requirements of measuring a variety of conductive fluids;
The converter adopts programmable frequency low frequency rectangular wave excitation. It improves the stability of flow measurement and has low power loss;
The converter adopts 16-bit embedded microprocessor. Full digital processing, fast calculation speed. Strong anti-interference ability, reliable measurement. High accuracy, flow measurement range up to 1500:1;
High-definition backlit LCD display. Easy to use, simple to operate, easy to learn and understand;
With RS485 or RS232 digital communication signal output;
With conductivity measurement function, it can judge whether the sensor is empty or not. With self-check and self-diagnosis function;
Adopt SMD devices and surface mount (SMT) technology. High circuit reliability;
Can be used in corresponding explosion-proof occasions.
Flanged Magnetic Flow Meter provide highly accurate flow measurement for a wide variety of conductive fluid applications. Magnetic Water Flow Meter is a volumetric flow meter that measures liquids or liquid slurries that have a minimum conductivity of 5 µS/cm. Based on Faraday’s law of electromagnetic induction. Magnetic Water Flow Meter is ideal for wastewater applications or any dirty liquid which is conductive or water based. It is widely used in water treatment, environmental protection sewage measurement and control, papermaking and other industrial and agricultural production processes for flow measurement and control.
Not affected by changes in fluid density, viscosity, temperature, pressure and conductivity. The linear measurement principle can achieve high-precision measurement;
There are no flow blocking parts in the measuring pipe. The pressure loss is small, and the requirements for straight pipe sections are low;
Nominal diameter DN6-DN3000 covers a wide range. There are many choices of lining and electrodes. It can meet the requirements of measuring a variety of conductive fluids;
The converter adopts programmable frequency low frequency rectangular wave excitation. It improves the stability of flow measurement and has low power loss;
The converter adopts 16-bit embedded microprocessor. Full digital processing, fast calculation speed. Strong anti-interference ability, reliable measurement. High accuracy, flow measurement range up to 1500:1;
High-definition backlit LCD display. Easy to use, simple to operate, easy to learn and understand;
With RS485 or RS232 digital communication signal output;
With conductivity measurement function, it can judge whether the sensor is empty or not. With self-check and self-diagnosis function;
Adopt SMD devices and surface mount (SMT) technology. High circuit reliability;
Can be used in corresponding explosion-proof occasions.
Size | DN3-DN3000mm (1/8”~120”) |
Accuracy | ±0.5% of reading,velocity >0.3 m/s |
Conductivity | Normal liquid >5 μS/cm,DI water >20 μS/cm |
Velocity | 0.1-15 m/s |
Protection Grade | IP65 Compact, IP68 Seperated |
Power Supply | AC85~250V, DC20V~36V |
Electrode Type | Fixed, Scraper |
Power Consumption | <20W |
Signal Output | 4~20 mA,pulse |
Communication | RS485/Modbus,Hart over 4~20 mA, Hart,Profitbus |
Language | English,Chinese (Other languages can be provided on request) |
Display | LC Display,128X128mm, Three lines, 4 internal push buttons |
Ambient Temperature | -25 ~ +60℃ /-77 ~ 140℉ Sensor -10~ +60℃ /-50~140℉ Convertor |
Liquid Temperature | Integrated: 70℃/ 158℉ max Seperated: 200℃/ 392℉max |
Relative Humidity | 5%~90% |
Exciting Current | 125mA, 187mA, 250mA, 500mA |
Exciting Frequency | 25Hz, 3.125Hz, 2.5Hz, 2Hz |
Measuring Tube | Stainless Steel 304 |
Flange | Carbon Steel (standard) |
Straight Pipe | Inlet Path ≥ 10D, Outlet Path ≥ 5D |
Certificates | CE 6022120716, ISO9001:2008, CQC1500155689521 |
Frequency Output | 1~5000 Hz |
Electrode | SS316L (standard), Hastelloy C, Hastelloy B,Titanium Tantalum, |
Liner Material | PTFE DN15-DN1600 -20℃ ~ +120 ℃ (-68℉~ 248℉) |
Process Pressure | 4.0 MPa (DN3-DN150) |
Flange Standard | ANSI B16.5 150#, 300#, 600# |
Electrode Material | Applications |
Stainless Steel 316L | Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,chemistry,carbamide,etc |
Hastelloy B (HB) | Having strong resistance to hydrochloric acid of any consistance which is below bioling piont. |
Hastelloy C (HC) | Be resistant to oxidable acid such as nitric acid,mixed acid,as well as oxidable salt such as Fe+++,Cu++aStnd sea water |
Titanium | Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid (including fuming nitric acid),organic acid,alkali etc. |
Tantalum | Having strong resistance to corrosive mediums that is similar with glass |
Platinum-iridium | Almost be applicable in all chemical mediums except for ammonium salt. |
Stainless Steel Covered | Applicable in mediums of no corrosive and low abrasion. |
Size | DN3-DN3000mm (1/8”~120”) |
Accuracy | ±0.5% of reading,velocity >0.3 m/s |
Conductivity | Normal liquid >5 μS/cm,DI water >20 μS/cm |
Velocity | 0.1-15 m/s |
Protection Grade | IP65 Compact, IP68 Seperated |
Power Supply | AC85~250V, DC20V~36V |
Electrode Type | Fixed, Scraper |
Power Consumption | <20W |
Signal Output | 4~20 mA,pulse |
Communication | RS485/Modbus,Hart over 4~20 mA, Hart,Profitbus |
Language | English,Chinese (Other languages can be provided on request) |
Display | LC Display,128X128mm, Three lines, 4 internal push buttons |
Ambient Temperature | -25 ~ +60℃ /-77 ~ 140℉ Sensor -10~ +60℃ /-50~140℉ Convertor |
Liquid Temperature | Integrated: 70℃/ 158℉ max Seperated: 200℃/ 392℉max |
Relative Humidity | 5%~90% |
Exciting Current | 125mA, 187mA, 250mA, 500mA |
Exciting Frequency | 25Hz, 3.125Hz, 2.5Hz, 2Hz |
Measuring Tube | Stainless Steel 304 |
Flange | Carbon Steel (standard) |
Straight Pipe | Inlet Path ≥ 10D, Outlet Path ≥ 5D |
Certificates | CE 6022120716, ISO9001:2008, CQC1500155689521 |
Frequency Output | 1~5000 Hz |
Electrode | SS316L (standard), Hastelloy C, Hastelloy B,Titanium Tantalum, |
Liner Material | PTFE DN15-DN1600 -20℃ ~ +120 ℃ (-68℉~ 248℉) |
Process Pressure | 4.0 MPa (DN3-DN150) |
Flange Standard | ANSI B16.5 150#, 300#, 600# |
Electrode Material | Applications |
Stainless Steel 316L | Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,chemistry,carbamide,etc |
Hastelloy B (HB) | Having strong resistance to hydrochloric acid of any consistance which is below bioling piont. |
Hastelloy C (HC) | Be resistant to oxidable acid such as nitric acid,mixed acid,as well as oxidable salt such as Fe+++,Cu++aStnd sea water |
Titanium | Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid (including fuming nitric acid),organic acid,alkali etc. |
Tantalum | Having strong resistance to corrosive mediums that is similar with glass |
Platinum-iridium | Almost be applicable in all chemical mediums except for ammonium salt. |
Stainless Steel Covered | Applicable in mediums of no corrosive and low abrasion. |
-Manuals
Flanged Magnetic Flow Meter
-Data sheet
-Manuals
Flanged Magnetic Flow Meter
-Data sheet
Flanged electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and wastewater, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry.
The premise of using Magnetic Water Flow Meter is that the measured liquid must be conductive. The conductivity of the liquid cannot be lower than the threshold, the lower limit. If the conductivity is lower than the threshold, it will cause measurement error until it can not be used.
It can be measured even if the value exceeds the threshold, and the indication error does not change much. The threshold value of general electromagnetic flowmeter is between 10-4~(5×10-6)S/cm, depending on the model. It also depends on the length of the flow signal line between the sensor and the converter and its distributed capacitance. The product manual usually stipulates the signal line length corresponding to the conductivity.
Flow Meter Equivalent
Our magnetic flow meters has reliable performance and low price, can be equivalent of many top brands magnetic flow meters, below is the replacement magnetic flow meter brands and series at low cost.
Endress+Hauser, promag series flow meter cheap equivalent
KROHNE ,OPTIFLUX mag flow meter economical replacement
ABB electromagnetic flow meter low cost inexpensive replace
Yokogawa’s ADMAG series magnetic flow meters equivalent
Rosemount 8750W Magnetic Flow Meter, 8700W series replacement at low price cost and fast delivery time.
Flanged electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and wastewater, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry.
The premise of using Magnetic Water Flow Meter is that the measured liquid must be conductive. The conductivity of the liquid cannot be lower than the threshold, the lower limit. If the conductivity is lower than the threshold, it will cause measurement error until it can not be used.
It can be measured even if the value exceeds the threshold, and the indication error does not change much. The threshold value of general electromagnetic flowmeter is between 10-4~(5×10-6)S/cm, depending on the model. It also depends on the length of the flow signal line between the sensor and the converter and its distributed capacitance. The product manual usually stipulates the signal line length corresponding to the conductivity.
Flow Meter Equivalent
Our magnetic flow meters has reliable performance and low price, can be equivalent of many top brands magnetic flow meters, below is the replacement magnetic flow meter brands and series at low cost.
Endress+Hauser, promag series flow meter cheap equivalent
KROHNE ,OPTIFLUX mag flow meter economical replacement
ABB electromagnetic flow meter low cost inexpensive replace
Yokogawa’s ADMAG series magnetic flow meters equivalent
Rosemount 8750W Magnetic Flow Meter, 8700W series replacement at low price cost and fast delivery time.