  • Medium temperature can be -20℃~200℃.
  • Integrated vertification,diagnostic function and empty pipe detection.
  • Measure forward and reverse direction flows.
  • Built-in reference electrodes,no need to connect ground ring.
  • Dual frequency excitation and stable zero point.
  • Precision coil winding technology,makes magnetic field more uniform.
  • High protection grade,IP65.
  • No moving parts,no pressure loss.
  • High accuracy: ±0.5% of reading,±0.3% and ±0.2% optional,velocity >0.3 m/s.
Availability:
Quantity:


Flanged Magnetic Flow Meter Introduction

Flanged Magnetic Flow Meter provide highly accurate flow measurement for a wide variety of conductive fluid applications. Magnetic Water Flow Meter is a volumetric flow meter that measures liquids or liquid slurries that have a minimum conductivity of 5 µS/cm. Based on Faraday’s law of electromagnetic induction. Magnetic Water Flow Meter is ideal for wastewater applications or any dirty liquid which is conductive or water based. It is widely used in water treatment, environmental protection sewage measurement and control, papermaking and other industrial and agricultural production processes for flow measurement and control.

Flanged Magnetic Flow Meter Features


            

    • Not affected by changes in fluid density, viscosity, temperature, pressure and conductivity. The linear measurement principle can achieve high-precision measurement;

    • There are no flow blocking parts in the measuring pipe. The pressure loss is small, and the requirements for straight pipe sections are low;

    • Nominal diameter DN6-DN3000 covers a wide range. There are many choices of lining and electrodes. It can meet the requirements of measuring a variety of conductive fluids;

    • The converter adopts programmable frequency low frequency rectangular wave excitation. It improves the stability of flow measurement and has low power loss;

    • The converter adopts 16-bit embedded microprocessor. Full digital processing, fast calculation speed. Strong anti-interference ability, reliable measurement. High accuracy, flow measurement range up to 1500:1;

    • High-definition backlit LCD display. Easy to use, simple to operate, easy to learn and understand;

    • With RS485 or RS232 digital communication signal output;

    • With conductivity measurement function, it can judge whether the sensor is empty or not. With self-check and self-diagnosis function;

    • Adopt SMD devices and surface mount (SMT) technology. High circuit reliability;

    • Can be used in corresponding explosion-proof occasions.

Flanged Magnetic Flow Meter Specification

Size                    

DN3-DN3000mm  (1/8”~120”)        

Accuracy                       

±0.5% of reading,velocity >0.3 m/s  

Conductivity

Normal liquid >5 μS/cm,DI water >20 μS/cm             

Velocity      

0.1-15 m/s

Protection Grade                               

IP65 Compact,  IP68 Seperated

Power Supply                                     

AC85~250V, DC20V~36V       

Electrode Type  

Fixed, Scraper

Power Consumption                          

 <20W    

Signal Output      

4~20 mA,pulse

Communication           

RS485/Modbus,Hart over 4~20 mA, Hart,Profitbus

Language                                        

English,Chinese (Other languages can be provided on request)   

Display                             

LC Display,128X128mm, Three lines, 4 internal push buttons  

Ambient Temperature                       

-25 ~ +60℃  /-77 ~ 140℉ Sensor      -10~ +60℃ /-50~140℉ Convertor

Liquid Temperature

Integrated: 70℃/ 158℉ max    Seperated: 200℃/ 392℉max

Relative Humidity    

5%~90%

Exciting Current    

125mA, 187mA, 250mA, 500mA

Exciting Frequency   

25Hz, 3.125Hz, 2.5Hz, 2Hz

Measuring Tube      

Stainless Steel 304

Flange          

Carbon Steel (standard)
Stainless Steel 304
Stainless Steel 316

Straight Pipe     

Inlet Path ≥ 10D,  Outlet Path ≥ 5D

Certificates        

CE 6022120716, ISO9001:2008, CQC1500155689521

Frequency Output     

1~5000 Hz

Electrode    

SS316L (standard), Hastelloy C, Hastelloy B,Titanium Tantalum,
Platinoiridium,Stainless Steel Covered Tungsten carbide       

Liner Material   

PTFE   DN15-DN1600    -20℃ ~ +120 ℃     (-68℉~ 248℉)
PFA    DN3-DN800         -20℃ ~ +120 ℃     (-68℉~ 248℉)
F46     DN25-DN1800     -20℃ ~ +120 ℃    (-68℉~ 248℉)
Neoprene   DN40-DN3000  -10℃ ~ + 80℃            (-50℉~ 176℉)
Polyurethane  DN40-DN1600  -10℃ ~ + 60℃      (-50℉~ 140℉)
FLS  DN40-DN1800      -10℃ ~ + 200℃                     (-50℉~ 392℉)

Process Pressure  

4.0 MPa (DN3-DN150)  
1.6 MPa (DN200-DN600)     
1.0 MPa (DN700-DN1000)
0.6 MPa (DN1200-DN3000)

Flange Standard

ANSI B16.5 150#, 300#, 600#
EN1092-1   PN10,PN16,PN25,PN40
JIS B2220   10K, 20K, 40K



Electrode Material

Applications

Stainless Steel 316L

Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,chemistry,carbamide,etc

Hastelloy B (HB)

Having strong resistance to hydrochloric acid of any consistance which  is below bioling piont.
Also resistable against vitriol,phosphate,hydrofluoricacid,organic acid etc which are oxidable acid,alkali and non-oxidable salt.

Hastelloy C (HC)

Be resistant to oxidable acid such as nitric acid,mixed acid,as well as oxidable salt such as Fe+++,Cu++aStnd sea water

Titanium

Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid (including fuming nitric acid),organic acid,alkali etc.
Not resistant to a pure reducing acid(such as sulphuric acid,hydrochloric acid  corrosion.
But if acid contains antioxidant is greatly reduce corrosion.

Tantalum

Having strong resistance to corrosive mediums that is similar with glass
Almost is applicable to all chemical mediums.
Except for hydrofluoric acid,oleum and alkali.

Platinum-iridium

Almost be applicable in all chemical mediums except for ammonium salt.

Stainless Steel Covered
Tungsten Carbide

Applicable in mediums of no corrosive and low abrasion.


-Manuals

Flanged Magnetic Flow Meter

-Data sheet


Flanged Magnetic Flow Meter Application

Flanged electromagnetic  flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and wastewater, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry.

The premise of using Magnetic Water Flow Meter is that the measured liquid must be conductive. The conductivity of the liquid cannot be lower than the threshold, the lower limit. If the conductivity is lower than the threshold, it will cause measurement error until it can not be used.

It can be measured even if the value exceeds the threshold, and the indication error does not change much. The threshold value of general electromagnetic flowmeter is between 10-4~(5×10-6)S/cm, depending on the model. It also depends on the length of the flow signal line between the sensor and the converter and its distributed capacitance. The product manual usually stipulates the signal line length corresponding to the conductivity.


Flow Meter Equivalent

Our magnetic flow meters has reliable performance and low price, can be equivalent of many top brands magnetic flow meters, below is the replacement magnetic flow meter brands and series at low cost.


Endress+Hauser, promag series flow meter cheap equivalent

KROHNE ,OPTIFLUX mag flow meter economical replacement

ABB electromagnetic flow meter low cost inexpensive replace

Yokogawa’s ADMAG series magnetic flow meters equivalent

Rosemount 8750W Magnetic Flow Meter, 8700W series replacement at low price cost and fast delivery time.


Previous: 
Next: