International drinking water approvals
Degree of protection IP68 (Type 6P enclosure)
2-line display with push buttons
Device as compact or remote version
HART
Availability: | |
---|---|
Quantity: | |
E+H Proline Promag 10W electromagnetic flow meter combines the Promag W sensor and the Promag 10 transmitter. The Promag sensors feature no pressure loss, no sensitivity to vibrations, and simple installation and commissioning. The Proline transmitters offer a uniform operating concept and a high degree of reliability and measuring stability.
0.03 to 33 ft/s (0.01 to 10 m/s) measuring range for liquids
Over 1000:1 operable flow range
Medium temperature range:
Hard rubber: 32 to 176°F (0 to 80°C)
Polyurethane: –4 to 122°F (–20 to 50°C)
PN 40, Class 300, 20K maximum process pressure
Accuracy
Current: ±5 μA
Pulse: ±0.5% o.r. ±0.08 in/s (±0.5% o.r. ±2 mm/s)
Max ±0.2% o.r. ±0.08 in/s (±0.2% o.r. ±2 mm/s) repeatability
≥50 μS/cm minimum conductivity
IP67, NEMA 4X standard
IP68, NEMA 6P optional for sensor for remote version
IEC, EN, NAMUR
E+H Proline Promag 10W electromagnetic flow meter combines the Promag W sensor and the Promag 10 transmitter. The Promag sensors feature no pressure loss, no sensitivity to vibrations, and simple installation and commissioning. The Proline transmitters offer a uniform operating concept and a high degree of reliability and measuring stability.
0.03 to 33 ft/s (0.01 to 10 m/s) measuring range for liquids
Over 1000:1 operable flow range
Medium temperature range:
Hard rubber: 32 to 176°F (0 to 80°C)
Polyurethane: –4 to 122°F (–20 to 50°C)
PN 40, Class 300, 20K maximum process pressure
Accuracy
Current: ±5 μA
Pulse: ±0.5% o.r. ±0.08 in/s (±0.5% o.r. ±2 mm/s)
Max ±0.2% o.r. ±0.08 in/s (±0.2% o.r. ±2 mm/s) repeatability
≥50 μS/cm minimum conductivity
IP67, NEMA 4X standard
IP68, NEMA 6P optional for sensor for remote version
IEC, EN, NAMUR
Electromagnetic
Sensor with degree of protection IP68 (Type 6P enclosure) with a highly cost-effective transmitter.
The specialist in the water and wastewater industry for the most demanding applications.
Flexible engineering – sensor with fixed or lap-joint process connections. Reliable measurement – accurate measured values even with 0 x DN inlet run. Maintenance‐free – no moving parts.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). 2-line display with push buttons.
Cost-effective – designed for easy applications and direct integration. Safe operation – display provides easily readable process information. Fully industry-compliant – IEC/EN/NAMUR.
Device as compact or remote version. HART.
DN 25...2000
1"...78"
Liner: polyurethane; hard rubber
Volume flow
±0,5% o.r. ± 2 mm/s (±0,5% o.r. ± 0,08 in/s)
9 dm3/min to 110 000 m3/h (2.5 gal/min to 700 Mgal/day)
PN 40, Class 300, 20K
'0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F)
–40 to +60 °C (–40 to +140 °F)
DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 25 to 2000 (1 to 78"): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate
Powder-coated die-cast aluminum
Degree of protection: IP66/67, type 4X enclosure; IP68, type 6P enclosure
Two line display
Push buttons
4...20mA + pulse,-/status (configurable)
HART
AC 20 to 28 V
AC 85 to 250 V
AC 20 to 28 V / DC 11 to 40 V
FM
CSA
CE, C-tick, EAC marking
Certificate/Test: PED/VDS
Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920
Electromagnetic
Sensor with degree of protection IP68 (Type 6P enclosure) with a highly cost-effective transmitter.
The specialist in the water and wastewater industry for the most demanding applications.
Flexible engineering – sensor with fixed or lap-joint process connections. Reliable measurement – accurate measured values even with 0 x DN inlet run. Maintenance‐free – no moving parts.
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). 2-line display with push buttons.
Cost-effective – designed for easy applications and direct integration. Safe operation – display provides easily readable process information. Fully industry-compliant – IEC/EN/NAMUR.
Device as compact or remote version. HART.
DN 25...2000
1"...78"
Liner: polyurethane; hard rubber
Volume flow
±0,5% o.r. ± 2 mm/s (±0,5% o.r. ± 0,08 in/s)
9 dm3/min to 110 000 m3/h (2.5 gal/min to 700 Mgal/day)
PN 40, Class 300, 20K
'0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F)
–40 to +60 °C (–40 to +140 °F)
DN 25 to 300 (1 to 12"): AlSi10Mg, coated
DN 25 to 2000 (1 to 78"): Carbon steel with protective varnish
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): Polycarbonate
Powder-coated die-cast aluminum
Degree of protection: IP66/67, type 4X enclosure; IP68, type 6P enclosure
Two line display
Push buttons
4...20mA + pulse,-/status (configurable)
HART
AC 20 to 28 V
AC 85 to 250 V
AC 20 to 28 V / DC 11 to 40 V
FM
CSA
CE, C-tick, EAC marking
Certificate/Test: PED/VDS
Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920