About Us | News | Download | Contact Us
Availability: | |
---|---|
Quantity: | |
A DIN rail is used to mount switches, relays, and transmitters. The rail itself is a piece of metal that is shaped to enable a device (such as a transmitter) to be attached using a spring clip, which slides into a bend in the metal rail and secures itself. The metal rail, complete with attached transmitter, can then be attached to a panel or a wall. The acronym DIN stands for Deutsches Institut fur Normung, which is the German Institute for Standardization. DIN rail transmitters, also called panel mount transmitters, are usually found in diverse applications because they are relatively low-cost and can operate with an array of different sensors. Because of the DIN rail configuration, they are also easy to install. They are somewhat less accurate than weather- and explosion-proof transmitters because of the longer wiring configuration necessary for securing the transmitter. For temperature transmitters, rail mounting is the oldest mounting method.
12.5mm slim Din-rail enclosure
2-wire, 4~20mA output with HART
Universal input - Thermocouple, RTD, Resistance, Voltage
7.5 to 48 VDC supply voltage range
-20 to +85 °C operating temperature
2KV AC RMS galvanic isolation
Resistance input upto 5K
Voltage input up-to 1000mV
Active temperature compensation
A DIN rail is used to mount switches, relays, and transmitters. The rail itself is a piece of metal that is shaped to enable a device (such as a transmitter) to be attached using a spring clip, which slides into a bend in the metal rail and secures itself. The metal rail, complete with attached transmitter, can then be attached to a panel or a wall. The acronym DIN stands for Deutsches Institut fur Normung, which is the German Institute for Standardization. DIN rail transmitters, also called panel mount transmitters, are usually found in diverse applications because they are relatively low-cost and can operate with an array of different sensors. Because of the DIN rail configuration, they are also easy to install. They are somewhat less accurate than weather- and explosion-proof transmitters because of the longer wiring configuration necessary for securing the transmitter. For temperature transmitters, rail mounting is the oldest mounting method.
12.5mm slim Din-rail enclosure
2-wire, 4~20mA output with HART
Universal input - Thermocouple, RTD, Resistance, Voltage
7.5 to 48 VDC supply voltage range
-20 to +85 °C operating temperature
2KV AC RMS galvanic isolation
Resistance input upto 5K
Voltage input up-to 1000mV
Active temperature compensation
Input | |
Input Signal | PT100,Cu50 and other RTD signals |
RTD Excitation Voltage | 2.5V |
Allowed Line Resistance | ≤100Ω |
Output | |
Output Signal | 4-20mA;0-20mA;0-10mA;0-5V;0-10V;1-5V;Customized |
Output Load Resistance | RL≤500Ω(output current signal); |
RL≥1KΩ(output voltage signal); | |
Other Parameters | |
Power Supply | DC24V,±10%;AC85-265V |
Current Consumption | ≤70mA(1 in 1 out,24V power supply,output 20mA); |
≤90mA(1 in 2out,24V power supply,output 20mA); | |
≤100mA(2 in 2 out,24V power supply,output 20mA); | |
Accuracy | 0.2%F.S. |
Temperature Drift | 0.005%F.S./℃ (-20℃~+55℃) |
Isolation Intensity | 1500V AC/1min(between input-ouput-power) |
Insulation Resistance | ≥100MΩ(between input-ouput-power) |
Working Temperature & Humidity | -20℃~+55℃ |
EMC | Complies with GB/T 18268(IEC61326-1) |
Applicable Equipment | 2-wires or 3-wires RTD |
Input | |
Input Signal | PT100,Cu50 and other RTD signals |
RTD Excitation Voltage | 2.5V |
Allowed Line Resistance | ≤100Ω |
Output | |
Output Signal | 4-20mA;0-20mA;0-10mA;0-5V;0-10V;1-5V;Customized |
Output Load Resistance | RL≤500Ω(output current signal); |
RL≥1KΩ(output voltage signal); | |
Other Parameters | |
Power Supply | DC24V,±10%;AC85-265V |
Current Consumption | ≤70mA(1 in 1 out,24V power supply,output 20mA); |
≤90mA(1 in 2out,24V power supply,output 20mA); | |
≤100mA(2 in 2 out,24V power supply,output 20mA); | |
Accuracy | 0.2%F.S. |
Temperature Drift | 0.005%F.S./℃ (-20℃~+55℃) |
Isolation Intensity | 1500V AC/1min(between input-ouput-power) |
Insulation Resistance | ≥100MΩ(between input-ouput-power) |
Working Temperature & Humidity | -20℃~+55℃ |
EMC | Complies with GB/T 18268(IEC61326-1) |
Applicable Equipment | 2-wires or 3-wires RTD |
-Manuals
Panel Mount or DIN Rail Mount Temperature Transmitters
-Data sheet
-Manuals
Panel Mount or DIN Rail Mount Temperature Transmitters
-Data sheet
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers converted signals from resistance thermometers (RTD) and thermocouples (TC), it also transfers resistance and voltage signals using HART® communication. Swift and easy operation, visualization and maintenance by PC using operating software. Space-saving DIN rail mounting according to IEC 60715
Temperature transmitter with HART® -Protocol for converting various input signals into a scalable 4 to 20 mA analog output signal
Input:
Resistance thermometer (RTD)
Thermocouple (TC)
Resistance transmitter (Ω)
Voltage transmitter (mV)
Field of application
Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers converted signals from resistance thermometers (RTD) and thermocouples (TC), it also transfers resistance and voltage signals using HART® communication. Swift and easy operation, visualization and maintenance by PC using operating software. Space-saving DIN rail mounting according to IEC 60715
Temperature transmitter with HART® -Protocol for converting various input signals into a scalable 4 to 20 mA analog output signal
Input:
Resistance thermometer (RTD)
Thermocouple (TC)
Resistance transmitter (Ω)
Voltage transmitter (mV)