sharethis sharing button
  • 0.065% Accuracy
  • 0.1% Stability per 5 years
  • 2,300 psi MWP
Availability:
Quantity:
  • EJA530-A

  • Yokogawa

Yokogawa EJA530A In-Line Mount Gauge Pressure Transmitter Introduction

The EJA-A series is Yokogawa’s most successful pressure transmitter line. First released in 1991, it continues to offer high performance and high reliability for any application. With an installed base of over 4-1/2 million EJA-A transmitters worldwide, it has a proven track record that makes it a true industry workhorse.

The EJA110A is the Traditional-mount Differential Pressure Transmitters in the series.

The high performance differential pressure transmitter model EJA110A can be used to measure liquid, gas, or steam flow as well as liquid level, density and pressure. It outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure. Model EJA110A also features remote setup and monitoring through communications.

The EJA Series is available with BRAIN, HART, FOUNDATION fieldbus or PROFIBUS PA communication protocols.

Yokogawa EJA530A In-Line Mount Gauge Pressure Transmitter Feature


  • The EJA530A is the In-line mount Gauge Pressure Transmitters in the series.


  EJA530A features include:

  • 0.2% Accuracy (0.075% Option)

  • 0.1% Stability for 1 year

  • 8,500 psi MWP


Yokogawa EJA530A In-Line Mount Gauge Pressure Transmitter Specification

EJA530A Overview

Measurement Types
Primary VariableGauge Pressure
Reference Accuracy
Primary Variable±0.2% of Span
Optional ±0.075 of Span (Capsule code A, B, or C)
Optional ±0.12 of Span (Capsule code D)
Stability (All Normal Operating Conditions)
Primary Variable±0.1% of URL per 1 year
Burst Pressure (Absolute)
EJA430A10,000 psi