About Us | News | Download | Contact Us
Availability: | |
---|---|
Quantity: | |
EJA430
Yokogawa
The EJA-A series is Yokogawa's most successful pressure transmitter line. First released in 1991, it continues to offer high performance and high reliability for any application. With an installed base of over 4-1/2 million EJA-A transmitters worldwide, it has a proven track record that makes it a true industry workhorse.Which Series is Right for You?
Refer to the General Specification sheet located under the 'Downloads' tab for detailed specifications.
EJA-E Series | EJX-A Series | |
---|---|---|
Accuracy | ||
± 0.025% | ● | |
± 0.040% | ● | ● |
± 0.055% | ● | |
Stability | ||
± 0.1% of URL per 15 years | ● | |
± 0.1% of URL per 10 years | ● | |
Response Time | ||
90 msec | ● | ● |
Mounting | ||
Traditional-mount | ● | ● |
In-line Mount | ● | ● |
Safety | ||
FMEDA Report | ● | ● |
IEC 61508 Certified (SIL 2) | ● | ● |
Specification Conformance | ||
±3σ | ● | ● |
Ambient Temperature Limits
(approval codes may affect limits)
−40 to 85 °C (−40 to 185 °F)
−30 to 80 °C (−22 to 176 °F) with LCD Display
Process Temperature Limits
(approval codes may affect limits)
−40 to 120 °C (−40 to 248 °F)
Ambient Humidity Limits
5 to 100 % RH @ 40 °C (104 °F)
Supply & Load Requirements
(Safety approvals can affect electrical requirements)
With 24 V DC supply, up to a 570 Ω load can be used. See Figure 2.
Supply Voltage “◊”
10.5 to 42 V DC for general use and flameproof type
10.5 to 32 V DC for lightning protector (Optional code/A)
10.5 to 30 V DC for intrinsically safe, Type n, nonincendive, or non-sparking type Minimum voltage limited at 16.4 V DC for digital communications, BRAIN and HART
The EJA-A series is Yokogawa's most successful pressure transmitter line. First released in 1991, it continues to offer high performance and high reliability for any application. With an installed base of over 4-1/2 million EJA-A transmitters worldwide, it has a proven track record that makes it a true industry workhorse.Which Series is Right for You?
Refer to the General Specification sheet located under the 'Downloads' tab for detailed specifications.
EJA-E Series | EJX-A Series | |
---|---|---|
Accuracy | ||
± 0.025% | ● | |
± 0.040% | ● | ● |
± 0.055% | ● | |
Stability | ||
± 0.1% of URL per 15 years | ● | |
± 0.1% of URL per 10 years | ● | |
Response Time | ||
90 msec | ● | ● |
Mounting | ||
Traditional-mount | ● | ● |
In-line Mount | ● | ● |
Safety | ||
FMEDA Report | ● | ● |
IEC 61508 Certified (SIL 2) | ● | ● |
Specification Conformance | ||
±3σ | ● | ● |
Ambient Temperature Limits
(approval codes may affect limits)
−40 to 85 °C (−40 to 185 °F)
−30 to 80 °C (−22 to 176 °F) with LCD Display
Process Temperature Limits
(approval codes may affect limits)
−40 to 120 °C (−40 to 248 °F)
Ambient Humidity Limits
5 to 100 % RH @ 40 °C (104 °F)
Supply & Load Requirements
(Safety approvals can affect electrical requirements)
With 24 V DC supply, up to a 570 Ω load can be used. See Figure 2.
Supply Voltage “◊”
10.5 to 42 V DC for general use and flameproof type
10.5 to 32 V DC for lightning protector (Optional code/A)
10.5 to 30 V DC for intrinsically safe, Type n, nonincendive, or non-sparking type Minimum voltage limited at 16.4 V DC for digital communications, BRAIN and HART
Yokogawa's Gauge Pressure Transmitter with DPharp digital sensor offers the performance and device intelligence needed to get greater insight into your process.
Measurement Types
Primary Variable | Gauge Pressure |
---|---|
Reference Accuracy | |
Primary Variable | ±0.065% of Span |
Stability (All Normal Operating Conditions) | |
Primary Variable | ±0.1% of URL per 5 years |
8urst Pressure (Absolute) | |
EJA430A | 10,000 psi |
Yokogawa's Gauge Pressure Transmitter with DPharp digital sensor offers the performance and device intelligence needed to get greater insight into your process.
Measurement Types
Primary Variable | Gauge Pressure |
---|---|
Reference Accuracy | |
Primary Variable | ±0.065% of Span |
Stability (All Normal Operating Conditions) | |
Primary Variable | ±0.1% of URL per 5 years |
8urst Pressure (Absolute) | |
EJA430A | 10,000 psi |
-Manuals
Yokogawa EJA430 Gauge Pressure Transmitters
-Data sheet
-Manuals
Yokogawa EJA430 Gauge Pressure Transmitters
-Data sheet
Yokogawa gauge pressure (GP) transmitter compares a process pressure against local ambient air pressure. Gauge pressure transmitters have ports to sample the ambient air pressure in real-time. Today’s highly accurate gauge pressure transmitters can be affected by fluctuations in the local ambient pressure. Measurements above the ambient air pressure are represented as a positive number, while negative number represents measurements below ambient. A gauge pressure measurement is indicated by the letter ‘g’ following the unit of measure of the reading (i.e., inH₂O(g) or psig).
Example Industrial Applications: Open tank level, Line pressure, and Blanket pressure in a tank.
Yokogawa gauge pressure transmitters use digital DPharp sensor technology to get accurate, reliable readings to you quickly.
Yokogawa gauge pressure (GP) transmitter compares a process pressure against local ambient air pressure. Gauge pressure transmitters have ports to sample the ambient air pressure in real-time. Today’s highly accurate gauge pressure transmitters can be affected by fluctuations in the local ambient pressure. Measurements above the ambient air pressure are represented as a positive number, while negative number represents measurements below ambient. A gauge pressure measurement is indicated by the letter ‘g’ following the unit of measure of the reading (i.e., inH₂O(g) or psig).
Example Industrial Applications: Open tank level, Line pressure, and Blanket pressure in a tank.
Yokogawa gauge pressure transmitters use digital DPharp sensor technology to get accurate, reliable readings to you quickly.