E+H Proline Promag P 300 electromagnetic flow meter measures volume flow, conductivity and mass flow. It is designed for chemical and process applications with corrosive liquids and the highest media temperatures. The bidirectional measuring principle is not dependent on pressure, density, temperature and viscosity. Because it has no moving parts, the Promag P 300 is maintenance-free and applications suffer no pressure loss due to cross-section constriction.
Measures volume flow, conductivity & mass flow
DN 15 to 600 (1/2 to 24 in) nominal diameter range
Media Temperature Ranges:
PFA liner: –4 to 302°F (–20 to 150°C)
PFA high-temp liner: –4 to 356°F (–20 to 180°C)
PTFE liner: –40 to 266°F (–40 to 130°C)
Up to 3 Outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
Pulse/frequency/switch output (active/passive)
Relay output
Maximum Measured Error:
Volume flow (standard): ±0.5%
Volume flow (optional): ±0.2%
PN 40, Class 300, JIS 20K maximum process pressure
No pressure loss due to cross-section constriction
4-line backlit display option
IP66/67, Type 4X standard enclosure
IP69 (optional)
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC (optional)
Heartbeat Technology (optional)
Predecessors include: Promag 50E, Promag 50P, Promag 51P, Promag 53E, Promag 53P
Electromagnetic
High-temperature flowmeter for process applications with a compact, easily accessible transmitter.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 600 (24"). All common Ex approvals.
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Liner made of PTFE or PFA. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
DN 15 to 600 (½ to 24")
Liner: PFA; PTFE
Electrodes: 1.4435 (F316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Volume flow, conductivity, mass flow
Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
4 dm⊃3;/min to 9600 m⊃3;/h (1 gal/min to 44 000 gal/min)
PN 40, Class 300, 20K
Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F)
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
DN 15 to 300 (½ to 12""): AlSi10Mg, coated
DN 350 to 600 (14 to 24""): Carbon steel with protective varnish
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; stainless steel for hygenic transmitter design
Standard: IP66/67, Type 4X enclosure
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
3 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output
Status input
4-20 mA input
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)
ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, UK Ex
CE, C-tick, EAC marking
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-Manuals
E+H Proline Promag P 300 Electromagnetic Flow Meter
-Data sheet