Share to:
  • Test principle:ion current (limiting current )
  • Display mode:128×64 matrix dot LCD
  • Test range:10.00% ~ 99.99% O2
  • Resolution:0.01%
  • Accuracy:≤±1%FS
  • Repeatability:≤±1%
  • Response time:T90≤30S
Availability:
Quantity:

Oxygen Analyzers Introduction

Oxygen analyzers provide valuable measurements in combustion control, process quality, safety and environmental applications. These are used in a variety of measurement scenarios including, but not limited to, boiler trimming in power plants, furnace optimization in refinery and petrochemical applications, process safety in vent headers, and product quality in ethylene production.

oxygen analyzer is a practical and reliable automatic analytical instrument. It can cooperate with various electric unit meters, conventional display recording instruments and DCS distributed control system to quickly and correctly detect and analyze the flue gas content generated by combustion equipment such as boilers, kiln and heating furnaces. . To achieve low-oxygen combustion control, to achieve energy-saving purposes, reduce environmental pollution.

Oxygen Analyzers Feature

• The built-in sensor is convenient for the users to install;

• The built-in sensor temperature-compensation circuit could avoid the influence from the temperature change on the measured accuracy;

• Altitude measurement module can be expanded to avoid the influence from atmospheric pressure change on the measured accuracy;

• The sensor is with no electricity on no consumption, long serving life and easy to maintain for features, etc;;

• No reference gas is needed and the analyzer will not be influenced by oxygen purity in work around atmosphere;

• Imported limiting current sensor is adopted with a rapid response speed, high accuracy and long calibration cycle for features, etc;

• With the functions of built-in compensation and sensor protection, the analyzer can be on power under 99.99% condition without affecting the sensor’s serving life;

• The frame mount installation mode makes it simple and convenient to install;

• With the function of built-in temperature compensation, the sample gas flow wouldn’t bring error to the measurement of the sensor;

• The measured accuracy of the whole range can be met by a random point calibrated, making the operation simple and convenient.


Oxygen Analyzers Specification 

1 Basic error: <±2%F•S, meter accuracy level 1
2 range: 0 ~ 5% O2; 0 ~ 10% O2; 0 ~ 20% O2; 0 ~ 25% O2
3 Background correction: -20mV ~ +20mV
4 measured flue gas temperature: JZY-II type is lower than 700 °C (low temperature type) JZY-I type 700 ~ 1200 °C (high temperature type)
5 Output signal: Scalable dual isolated output, 0~10mADC and 4~20mADC, optically isolated, directly connected to the computer.
6 Load capacity: 0 ~ 1.2 Κ Ω or 0 ~ 600 Ω
7 Environmental conditions: 0 ~ 50 ° C; relative humidity <90%
8 Power supply: 220V±10%, 50Hz
9 Power consumption: The transmitter is about 8W, and the heating furnace is about 50W on average.
10 response time: 90% for about 3 seconds
Zirconium oxide probe heating furnace heating time: about 20 minutes


Parameter function
Loc: To set the following parameters, first set Loc to 808. After the setting is finished, set Loc to other values to prevent misoperation and change the setting value.
dA: equal to zero current output is 0~10mA, not equal to zero current output is 4~20mA
SC: the unit for the oxygen potential migration of the sensor is mV
dIL: 0 — +20.00, linear input zero display value
dIH: 0 — +20.00, linear input full scale display value
Corresponding to dIL~dIH, 7 and 8 pin output current 4~20mA
CC: Heating temperature setting value, when the temperature reaches the set value, the meter automatically stops heating and maintains this temperature.