About Us | News | Download | Contact Us
Availability: | |
---|---|
Quantity: | |
Glass Tube Rotameter is a Variable Area Flow Meter. A rotameter consists of a tapered tube, typically made of glass, with a 'float' made of SS or PTFE. The differentila pressure across the annulus area is constant. The float moves through the tapered tube up and down with respect to fluid flow. The vertical position of the float as indicated by scale is the measure of the instantaneous flow rate.
Heavy Duty Design with Maximum Visibility
Two Tone Powder Coated Excellent Finish
No Threads in Body, Avoids Corrosion
Easy to Maintain and Replace
Suitable for on Line Installation
Single Piece (Joint-less) PTFE/ PFA/ PP cladded end connections
Glass Tube Rotameter is a Variable Area Flow Meter. A rotameter consists of a tapered tube, typically made of glass, with a 'float' made of SS or PTFE. The differentila pressure across the annulus area is constant. The float moves through the tapered tube up and down with respect to fluid flow. The vertical position of the float as indicated by scale is the measure of the instantaneous flow rate.
Heavy Duty Design with Maximum Visibility
Two Tone Powder Coated Excellent Finish
No Threads in Body, Avoids Corrosion
Easy to Maintain and Replace
Suitable for on Line Installation
Single Piece (Joint-less) PTFE/ PFA/ PP cladded end connections
Materials of Construction
Performance
Tube : Borosilicate Glass
Float : SS316, PTFE, other on request
Packings : Neoprene, PTFE, Silicon, VITON
End Fitting : Mild steel, Carbon steel, SS304, SS316,
CF-8M, CF8, Cast Iron PTFE lined,
SS lined, PVC, and any other desired material
subject to its availability.
Frame & : Mild Steel, SS (optional)
Cover
Accuracy : ± 2% of full flow
Repeatability : 0.5%
Rangeability : 10:1
Scale length : 175-200 mm,
250mm (Optional), 500 mm (optional) 0
Max. Temp. : Up to 200 C,
depending upon gland packing material
Connections : Flanged or Threaded
Enclosure : IP 55 or IP65 on request
Model | DN (mm) | Measure range (L/H) | Accuracy (±%) | Medium | D | E | |||
Water(20℃) | Air (101325Pa 20℃) | Working temp | Working Pressure | ||||||
DK800-4 DK800-4F | 4 | 0.25-2.5 | 0.5-5 0.8-8 1.6-16 4-40 6-60 | 2.5 | -20℃~ +120℃ | ≤1.0MPa | φ11 | M10×1 | |
DK800-6 DK800-6F | 6 | 0.5-5 1.2-12 2.5-25 4-40 6-60 10-100 16-160 | 10-100 25-250 50-500 80-800 100-1000 180-1800 240-2400 300-3000 350-3500 430-4300 |
Materials of Construction
Performance
Tube : Borosilicate Glass
Float : SS316, PTFE, other on request
Packings : Neoprene, PTFE, Silicon, VITON
End Fitting : Mild steel, Carbon steel, SS304, SS316,
CF-8M, CF8, Cast Iron PTFE lined,
SS lined, PVC, and any other desired material
subject to its availability.
Frame & : Mild Steel, SS (optional)
Cover
Accuracy : ± 2% of full flow
Repeatability : 0.5%
Rangeability : 10:1
Scale length : 175-200 mm,
250mm (Optional), 500 mm (optional) 0
Max. Temp. : Up to 200 C,
depending upon gland packing material
Connections : Flanged or Threaded
Enclosure : IP 55 or IP65 on request
Model | DN (mm) | Measure range (L/H) | Accuracy (±%) | Medium | D | E | |||
Water(20℃) | Air (101325Pa 20℃) | Working temp | Working Pressure | ||||||
DK800-4 DK800-4F | 4 | 0.25-2.5 | 0.5-5 0.8-8 1.6-16 4-40 6-60 | 2.5 | -20℃~ +120℃ | ≤1.0MPa | φ11 | M10×1 | |
DK800-6 DK800-6F | 6 | 0.5-5 1.2-12 2.5-25 4-40 6-60 10-100 16-160 | 10-100 25-250 50-500 80-800 100-1000 180-1800 240-2400 300-3000 350-3500 430-4300 |
-Manuals
Glass Tube Rotameter
-Data sheet
-Manuals
Glass Tube Rotameter
-Data sheet
Glass rotameter flow meter is used to measure the instantaneous single-phase non-pulasting flux of liquid or gas in pipe in areas such as chemical,pertolum.medicine,dirtilizer ,food, sugar refinery,paper making,light industry ,textile,printing and dyeing,envirnmental pretection etc.PTFE,the high quality corrosion resistant material is used at the main contact parts of the corrosion resistant glass rotameter flow meter to contact the medium, it has a very good perfotmance of corrosion resistance in measuring various kinds of flow of strong acid(except hydroflucric acid) alkali,oxidant ,strong oxidation acid.organic solvent and other corrosive gas and liquid.
Various industries
Process or carrier gases
Purge fluids for measuring systems
Air or water
Nitrogen, CO2 or other inert gases
Sample flow monitoring in gas analysers etc.
Gas sparging in liquids
Conventional and nuclear power industry
Air, gases (nitrogen, hydrogen, methane etc.)
Water
Glass rotameter flow meter is used to measure the instantaneous single-phase non-pulasting flux of liquid or gas in pipe in areas such as chemical,pertolum.medicine,dirtilizer ,food, sugar refinery,paper making,light industry ,textile,printing and dyeing,envirnmental pretection etc.PTFE,the high quality corrosion resistant material is used at the main contact parts of the corrosion resistant glass rotameter flow meter to contact the medium, it has a very good perfotmance of corrosion resistance in measuring various kinds of flow of strong acid(except hydroflucric acid) alkali,oxidant ,strong oxidation acid.organic solvent and other corrosive gas and liquid.
Various industries
Process or carrier gases
Purge fluids for measuring systems
Air or water
Nitrogen, CO2 or other inert gases
Sample flow monitoring in gas analysers etc.
Gas sparging in liquids
Conventional and nuclear power industry
Air, gases (nitrogen, hydrogen, methane etc.)
Water