  • Flange process connection
  • -40 to 176°F (-40 to 80°C) temp range
  • 10 to 36psi (0.7 to 2.5bar) pressure range
  • Maximum measuring distance:
    • Liquids 50ft (15m)
    • Solids 23ft (7m)
  • Blocking distance: Liquids and Solids 0.6m (2ft)
  • International explosion protection certificate
Availability:
Quantity:

E+H Prosonic FMU43 Ultrasonic Sensor Introduction

E+H Prosonic FMU43 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks, agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis. Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.

E+H Prosonic FMU43 Ultrasonic Sensor Feature


  • Reliable non-contact measurement

  • Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable

  • Envelope curves on the on-site display for simple diagnosis

  • Hermetically sealed and potted sensor

  • Chemically resistant sensor out of PVDF

  • Calibration without filling or discharging

  • Integrated temperature sensor for automatic correction of the temperature dependent sound velocity

E+H Prosonic FMU43 Ultrasonic Sensor Specification 

    • Measuring principle

      Ultrasonic

    • Characteristic / Application

      Compact ultrasonic transmitter

    • Supply / Communication

      4-wire (HART), PROFIBUS PA, FOUNDATION Fieldbus

    • Accuracy

      +/- 4 mm or +/- 0.2 %of set measuring range

    • Ambient temperature

      -40 °C ... 80 °C
      (-40 °F ... 176 °F)

    • Process temperature

      -40 °C ... 80 °C
      (-40 °F ... 176 °F)

    • Process pressure absolute / max. overpressure limit

      0.7 bar ... 2.5 bar abs
      (10 psi ... 36 psi)

    • Main wetted parts

      Unsaturated Polyester, 316 Ti

    • Process connection

      DN 100, ASME 4"

    • Blocking distance

      0.6 m (2 ft)

    • Application

      Application

    • Max. measurement distance

      Max. measurement distance

    • Communication

      4 ... 20 mA HART
      PROFIBUS PA
      FOUNDATION Fieldbus

    • Certificates / Approvals

      ATEX, FM, CSA, NEPSI

    • Application limits

      Application limits